G5W11, IP67, up to 10(2)A 125/250VAC
G5W11, IP67, up to 10(2)A 125/250VAC
Feature
- Rating
W1: 0.1A 48VDC, 0.1A 125/250VAC T85 (cURus);0.1A 48VDC, 0.1A 125/250VAC µ40T85 5E4(Nemko, ENEC17, CQC)
W2: 5A125/250VAC 5A 38VDC T85 (cURus);5A 125/250VAC~5A 30VDC µ40T85 5E4(Nemko, ENEC17, CQC)
W3: 10.1A 1/10HP 125/250VAC, 0.5A 125VDC, 0.25A 250VDC T85 (cURus);10(2)A 125/250VAC~ 0.5A 125VDC 0.25A 250VDC µ40T85 5E4 (Nemko, ENEC17, CQC) - Initial contact resistance : 50m ohms MAX. for terminal typer; 100m ohms MAX. for wire type or depends on the wire length
- Insulation resistance : 100M ohm MIN. at 500VDC
- Dielectric strength : 1000VAC (50~60Hz) 1 min. between terminal, 1500VAC (50~60Hz) 1 min. between terminal and housing
- Electrical life : 10,000 cycles min (UL)
- Safety approved internationally by cURus in North America, Nemko ENEC in Europe, CQC in Asia
- IP67 protection level for wire type (cURus, Nemko ENEC17, CQC), terminal type is without waterproof.
- SPST-NC, SPST-NO or SPDT
- Wide range of wiring terminals and levers
- Applications in automotive, agricultural, automatic and office equipment
Specification
How to order
Item