MR6 SERIES
DOUBLE  POLE ROCKER SWITCHES UP TO 20A 125VAC
Soldering, PCB or  Quick Connecting  Terminals, High Inrush Current up to 141A on request

 

  • UL61058-1 (cURus , ENEC15)
    12(4)A 125/250V ~T55, T125/55 6E3, 1E4
    16(8)A 125/250V ~T55, T125/55 6E3, 1E4
    16A 6~30VDC, ~T55, T125/55 6E3, 1E4
    8[128]A 250V~ T55, 1E4
    TV-10 /125V~T55, 25E3
  • UL1054 approved: (cURus)
    20A 125VAC, 16A 250VAC 6E3
    TV-10 /125VAC 25E3
  • Initial contact resistance : 20m ohm (max.)
  • Insulation resistance : 100M ohm (min,) at 500VDC
  • Dielectric strength : 1,500VAC for 1 minute
  • Safety approved internationally by cURus in North America, ENEC15 in Europe
  • Standard 12.9x19.2mm snap-in cutout size
  • DPST, SPST circuitry
  • With or without illuminated type
  • Complete terminals options quick-connect, solder and PCB pins
  • Waterproof cover boot as optional accessory

How to order

What is Inrush Current? And why MR6?

Quoted from Wekipedia:
~Inrush current, input surge current or switch-on surge is the maximum, 
instantaneous input current drawn by an electrical device when first turned on. 
For example, incandescent light bulbs have high inrush currents until their 
filaments warm up and their resistance increases. Alternating current electric 
motors and transformers may draw several times......
~

Choosing a switch that can have a good capacity for your device is thus very 
important for your device's safety. Our MR6 series can offer an option up to TV10
or equivalent to 141A inrush that can be the appropriate switch to ensure
your device's life and stability.

 



MR6-210C5W-NBBB


MR6-212C5W-NBBB


MR6-211C2N-LBWB


MR6-211C5W-GBRB